Sign In | Join Free | My burrillandco.com
Home > EDI Water Treatment Plant >

1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System

    Buy cheap 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System from wholesalers
     
    Buy cheap 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System from wholesalers
    • Buy cheap 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System from wholesalers
    • Buy cheap 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System from wholesalers
    • Buy cheap 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System from wholesalers

    1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System

    Ask Lasest Price
    Brand Name : CKUNKE
    Model Number : CK-EDI
    Certification : CE,ISO
    Price : Negotiate
    Payment Terms : L/C, T/T, Western Union,paypal
    Supply Ability : 20 units per month
    Delivery Time : 7-15days
    • Product Details
    • Company Profile

    1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System

    1T/H ss304 Two-stage Reverse Osmosis System Plus EDI Module And PH Dosing System


    EDI Module compare to Mixing bed


    ItemEDIMixing bed
    Water production15~18MΩ·cm2~10MΩ·cm
    StabilityStable water qualityWater quality is affected by resin exchange and regeneration quality
    OperationalEasy to operate, no need for skilled workersHigh level of operator requirements during regeneration
    Environmental protection

    No acid or alkali,

    no chemical pollution

    Need acid-base regeneration, need to solve the problem of acid-base storage and emissions
    Continue to operateNo need to stop during regeneration, regeneration while runningNeed to stop regeneration when regenerating
    Operating expensesLowHigh
    Initial investmentHighLow

    EDI Module advantages


    1. The water quality of the produced water is high and stable;

    2. No acid or alkali regeneration is required;

    3, continuous operation, simple operation;

    4, the installation is simple and low cost;

    5. Modular design and convenient expansion;

    6. No regeneration pollution;

    7. Low construction area requirements;

    8. Low operating and maintenance costs;

    9, easy to integrate with the original processing system;

    10. No salt and concentrated water circulation system, high reliability.


    Main Components of 1T Two-stage RO+EDI Machine


    1, Original water pump

    The raw water pump provides the raw water pressure for the raw water pretreatment system. If the raw water is under pressure, you can completely avoid this equipment. General requirements for raw water pressure >=0.3MPa


    2, Original water tank

    The original water tank has a simpler function and is used for storing raw water. This is afraid that the original water will not be available for a transfer (usually adding a float switch is more automated than the entire system).


    3, Quartz sand filter

    Quartz sand filter material is used to remove suspended solids, sediment, impurities, etc. of larger particles in raw water to reduce the turbidity of water. Moreover, organic substances, bacteria, viruses, etc. in the water can be largely removed as the turbidity is lowered, and good conditions are created for post-filtration sterilization.


    4, Activated carbon filter

    The adsorption capacity of activated carbon is used to effectively adsorb organic matter, free residual chlorine, colloids, particles, microorganisms, certain metal ions and discoloration in raw water.


    The reverse osmosis system is the core component of the entire pure water system, and only through reverse osmosis can the standard of pure water be achieved. The reverse osmosis system mainly uses a membrane filtration process. The water molecules can then pass through the reverse osmosis membrane. Others such as calcium, magnesium, and sodium ions are discharged along with the wastewater. The following components of the system.


    1, Precision filter

    The filter primarily filters large particle molecules in the water.


    2, Special high pressure pump

    Generally, the high pressure pump we use here is the southern special pump. Provides strong power for reverse osmosis equipment.


    3, Two-stage reverse osmosis membrane

    The reverse osmosis membrane uses membrane filtration technology. Let water molecules pass through other ions to achieve the purpose of purifying water.


    4, EDI Module

    It cleverly combines electrodialysis and ion exchange technology, using high-pressure electrodes at both ends to move charged ions in water, and mixing ion exchange resin and selective resin film to accelerate ion removal.


    5, Auxiliary system

    For example, ozone sterilization system, light inspection, filling system. It can also be sterilized by ultraviolet rays, and there is no residue of ultraviolet rays.


    Detail Image of ​1T Two-stage RO+EDI Machine


    CNP Pressure pump


    1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System
    Ultraviolet sterilizer
    1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System
    EDI Module
    1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System

    Quality 1T/H Ss304 EDI Water Treatment Plant , Two Stage Reverse Osmosis System Plus PH Dosing System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Chunke Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)